NOVEMBER 2012
Volume 42, No. 11


Research Report

Test-Retest and Intrarater Reliability of 2-Dimensional Ultrasound Measurements of Distance Between Rectus Abdominis in Women

Patricia Mota, Augusto Gil Pascoal, Fatima Sancho, Kari Bø

DOI: 10.2519/jospt.2012.4115



STUDY DESIGN: Single-group test-retest reliability study. OBJECTIVES: To evaluate the test-retest intraobserver reliability of 2-dimensional ultrasound measurement of the distance between the rectus abdominis muscles, the interrectus distance (IRD). BACKGROUND: Diastasis recti is defined as the separation of the 2 rectus abdominis muscles, with a reported prevalence of between 30% and 70% in women during pregnancy and in the postpartum period. The condition is difficult to measure, and ultrasound imaging has been suggested as a useful method to quantify the diastasis. However, to date, no studies have investigated intratester or intertester reliability of ultrasound to measure the distance between the rectus abdominis muscles during rest and contraction. METHODS: Ultrasound images from the rectus abdominis were recorded in 24 healthy female volunteers at rest and under 2 conditions of abdominal contraction: abdominal crunch and drawing-in exercises. The probe was positioned at 2 locations: below and above the umbilicus. A blinded investigator measured the IRD offline from 2 different ultrasound images collected on 2 different days (test-retest). Additionally, reanalyses of the same ultrasound images were done on 2 separate occasions (intra-image). RESULTS: Test-retest measurements of IRD demonstrated good to very good reliability, with intraclass correlation coefficient values between 0.74 and 0.90. The only exception was for IRD measured 2 cm below the umbilicus during the abdominal crunch exercise, which had an intraclass correlation coefficient of 0.50. For intratester reliability of the same images, the intraclass correlation coefficient values were all above 0.90. CONCLUSION: Ultrasound imaging is a reliable method for measuring the IRD at rest and during abdominal crunch and drawing-in exercises.

J Orthop Sports Phys Ther 2012;42(11):940-946, Epub 18 July 2012. doi:10.2519/jospt.2012.4115

KEY WORDS: diastasis, postpartum, reliability, ultrasonography


The authors evaluate the test-retest intraobserver reliability of 2-dimensional ultrasound measurement of the distance between the rectus abdominis muscles, the interrectus distance (IRD).


Related Slides

(Right click the link below and select Save Target As...)

Nov2012-Mota.ppt