ADVERTISEMENT

MY JOSPT


SEARCH JOSPT

 

 




Powered by Ere

Print Buy

SEPTEMBER 1999
Volume 29, No. 9


Research Report

Association of KT-1000 Measurements With Clinical Tests of Knee Stability 1 Year Following Anterior Cruciate Ligament Reconstruction

Malachy P. McHugh, Stephen J. Nicholas, Timothy F. Tyler, Gilbert W. Gleim

Study Design: Prospective, observational study. Objectives: To determine the association between KT-1000 measurements with an anterior translation force of 89 N and other measures of outcome (the Tegner activity score, the modified Lysholm score, subjective rating of instability, Lachman test, and pivot-shift test) 1 year following anterior cruciate ligament (ACL) reconstruction. Background: Health care professionals often use the side-to-side difference measured with the KT-1000 arthrometer to determine ACL integrity during passive motion. It has been postulated that a 5-mm or greater difference between impaired and nonimpaired knees represents a procedural failure. Methods and Measures: Ninety patients (46 men, 44 women) with a mean age of 30 ± 8 years were examined 1 year after surgery. Patients were classified in 1 of 3 groups depending on the amount of laxity between the impaired knee and the nonimpaired knee. Seventy percent of the subjects had a side-to-side difference less than or equal to 3 mm (tight), 13% had a difference of between 3 and 5 mm (moderate), and 17% had a difference greater than or equal to 5 mm (loose) on examination using the KT-1000. Results: Mean Lysholm and Tegner scores did not differ significantly among groups. Side-to-side differences in KT-1000 measurements at 89 N were not associated with the Lysholm score (r = -0.09) or Tegner score (r = 0.02). Lachman tests were related to involved-knee KT-1000 measurements (r = 0.39) but not to side-to-side differences in KT-1000 measurements (r = 0.15). Similarly, pivot-shift tests were related to involved-knee KT-1000 measurements (r = 0.26) but not to side-to-side differences (r = -0.08). Conclusions: These results suggest that side-to-side KT-1000 measurements obtained with an anterior translation force of 89 N should not be used in isolation to determine ACL reconstruction success or failure 1 year following surgery. J Orthop Sports Phys Ther. 1999;29(9):540-545. Key Words: anterior tibial translation, arthrometer, outcome measures